VCAP-DCV Design 2022 3V0-21.21 Practice Exam Questions

VCAP-DCV Design 2022 3V0-21.21 Practice Exam Questions

If you’re studying for the 3V0-21.21 Advanced Design VMware vSphere 7.x exam and want to get the VCAP-DCV Design 2022 certification, you’ve come to the correct place. FreeTestShare 3V0-21.21 Practice Exam including exam questions and answers, was created by our professional IT lecturers and contained the most recent 3V0-21.21 exam questions. The newest 3V0-21.21 Practice Exam Questions are based on the exam objectives and are designed to help you assess your understanding. It will help you pass your VMware 3V0-21.21 exam successfully in the first try.

To assess your level of preparation, take this 3V0-21.21 practice test first!

Page 1 of 3

1. Which two statements are true about gathering functional business and application requirements? (Choose two.)

2. A customer is deploying a new cluster and wants to be able to patch and update two hosts in parallel. The cluster must be able to maintain N+1 resiliency across the remaining hosts while patching activities are performed. The current expected utilization of the platform requires a minimum of two hosts to support all of the virtual machines.

What is the minimum number of hosts the customer will require in the cluster in order to meet the required resiliency level?

3. An organization’s data scientists are executing a plan to use machine learning (ML). They must have access to graphical processing unit (GPU) capabilities to execute their computational models when needed. The solutions architect needs to design a solution to ensure that GPUs can be shared by multiple virtual machines.

Which two solutions should the architect recommend to meet these requirements? (Choose two.)

4. An architect is tasked with designing a new VMware software-defined data center (SDDC) using VMware vSAN. The architect uses a storage assessment tool to determine the storage requirements for the new vSAN cluster. The new SDDC is going to be deployed

into the existing data center and must be connected to a shared core network switch.

The architect decides to use vSAN ReadyNodes with the following configuration:

✑ Two disk groups with:

✑ uk.co.certification.simulator.questionpool.PList@f9f0a80

✑ Four 10 GbE ports

Which element represents a risk that should be included in this design?

5. A customer requests a review of its current vSphere platform design.

The following information is noted:

✑ There are three different workload profiles for the virtual machines:

✑ uk.co.certification.simulator.questionpool.PList@e1b4da0

✑ Tier-1, Tier-2 and Tier-3 virtual machines are all hosted on a single large vSphere cluster.

✑ The Chief Information Security Officer (CISO) has raised concerns that hosting externally facing applications alongside management tools does not meet internal compliance standards.

✑ The Operations team has raised concerns about Tier-1 virtual machines negatively impacting the performance of vCenter Server.

✑ The Operations lead has stated that management changes have consistently been rejected by application teams.

As a result of the review, which recommendation should the architect make regarding the design of this platform?

6. During a requirements gathering workshop, the customer provides the following requirement (REQ) and constraints (CON):

✑ REQ01: The customer is looking for a way to limit database virtual machine (VM) placement to save on CPU licensing costs.

✑ CON01: There is a single cluster with no budget to scale.

✑ CON02: All virtual machines must run on the consolidated cluster.

Which two design decisions should the architect make to meet the customer requirement? (Choose two.)

7. A customer requires the use of data encryption to ensure data is not accessible when a drive is removed from the primary storage platform. However, there is also a requirement to use deduplication and compression against all workloads in order to conserve space.

Which solution meets the customer requirements?

8. Which requirement would be classified as a functional requirement within the application design documentation?

9. An architect is designing storage for a new vSphere environment to meet the following requirements:

✑ Asynchronous replication is required between two sites.

✑ The impact on the storage layer should not impact the performance of the compute layer.

✑ Each application tier will require different replication attributes.

✑ Virtual machine live migration across compute and storage must be supported.

✑ Virtual machine aware back up will be leveraged.

✑ Operational management overhead should be minimized.

✑ Operational automation should be supported.

Which storage design recommendations would meet the requirements?

10. In a meeting to discuss the minimum viable product (MVP) deployment of a new customer-facing application, the key stakeholder shares details of the application components and the application administrators share details of performance and integrity tests for the application.

The application will be made up of the following components:

✑ A web server

-Steps to confirm the web server is operating correctly will take 15 minutes after the application server is online.

✑ An application server

-Steps to confirm application server integrity will take 15 minutes after the database is online.

✑ A database server

-The database server will be managed by a database administrator, with an agreed service-level agreement (SLA) to restore and validate database services within one hour.

The existing VMware infrastructure offers a recovery point objective (RPO) of 5 minutes and recovery time objective (RTO) of 15 minutes through a combination of backups and replication.

In the event of an outage impacting all three application components, how long will it take for the application to recover and complete all checks?


 

Share this post

Leave a Reply

Your email address will not be published. Required fields are marked *